{| class="wikitable"
|+BLM thresholds, voltages and channel mapping
|-
|Name
|Type
|Gain
|S/N
|Threshold [pC]
|Voltage [-V]
|TBLM CH#
|TBLM#
|HV CH#
|LED CH#
|-
|EMBT:LIC5A
|LIC
|N/A
|N/A
|55
|500
|
|
|
|
|-
|EMBT:LIC3
|LIC
|N/A
|N/A
|150
|500
|
|
|
|
|-
|EMBD:LIC2
|LIC
|N/A
|N/A
|75
|500
|
|
|
|
|-
|EMBD:PMT3
|PMT
|3
|NM4292
|150
|50
|
|
|
|
|}

Revision as of 23:40, 19 May 2021

Medium energy beam loss monitor positions.

BLM thresholds, voltages and channel mapping
Name Type Gain S/N Threshold [pC] Voltage [-V] TBLM CH# TBLM# HV CH# LED CH#
EMBT:LIC5A LIC N/A N/A 55 500
EMBT:LIC3 LIC N/A N/A 150 500
EMBD:LIC2 LIC N/A N/A 75 500
EMBD:PMT3 PMT 3 NM4292 150 50